CVE-2026-62258
Description
HTSlib is a library for reading and writing bioinformatics file formats. Prior to 1.21.2, 1.22.3, 1.23.2, and 1.24, the CRAM decoder validates the 254-character query-name limit only after decoding the name into a 1024-byte stack array. An attacker-controlled CRAM record can provide an overlong query name and overflow the local stack buffer before the later validation runs; all CRAM format versions are affected. Opening such a file can crash the process, corrupt stack data, and may permit arbitrary code execution. This issue is fixed in versions 1.21.2, 1.22.3, 1.23.2, and 1.24.
AI Remediation Playbook Pro+
Get step-by-step remediation playbooks with specific commands, verification steps, and rollback procedures.
Upgrade to Pro+AI Attack Path AnalysisPro+
Visualize potential attack chains and lateral movement paths with AI-powered analysis.
AI Risk ForecastingPro+
Predict exploitation likelihood with AI-powered threat intelligence forecasting.
AI Compliance MappingPro+
Map vulnerabilities to compliance frameworks with AI-assisted gap analysis.
MITRE ATT&CK TechniquesThreat Intelligence
How attackers may exploit this vulnerability