Description

HTSlib is a library for reading and writing bioinformatics file formats. Prior to 1.21.2, 1.22.3, 1.23.2, and 1.24, the CRAM BETA decoder functions cram_beta_decode_long, cram_beta_decode_int, and cram_beta_decode_char, and the experimental CRAM v4 XPACK functions cram_xpack_decode_long and cram_xpack_decode_int, have bounds-checking flaws caused by integer overflow after a multiplication. The resulting incorrect bounds check can allow decoding to read beyond the supplied input buffer, potentially leaking process-state information or crashing the process. This issue is fixed in versions 1.21.2, 1.22.3, 1.23.2, and 1.24.