CVE-2026-80154
Description
All firmware versions of Lantronix SLC8000, SLC9000, EMG8500, EMG7500, SLB882, SLCx-03, and SLCx-02 contain an authentication bypass vulnerability in the web management portal that allows unauthenticated attackers to derive valid session tokens of logged-in users and bypass source IP and User-Agent validation. Session tokens are generated deterministically from the device model and the current time at one-second resolution, resulting in a small enumerable set of possible active tokens. Attackers can construct a crafted URI that exploits file extension handling in the web server path routing to bypass per-session source-address validation, then use a derived token from a different source address to gain elevated privileges on the affected device and potentially impact downstream serial-attached devices.
AI Remediation Playbook Pro+
Get step-by-step remediation playbooks with specific commands, verification steps, and rollback procedures.
Upgrade to Pro+AI Attack Path AnalysisPro+
Visualize potential attack chains and lateral movement paths with AI-powered analysis.
AI Risk ForecastingPro+
Predict exploitation likelihood with AI-powered threat intelligence forecasting.
AI Compliance MappingPro+
Map vulnerabilities to compliance frameworks with AI-assisted gap analysis.
Weakness Types (CWE)
MITRE ATT&CK TechniquesThreat Intelligence
How attackers may exploit this vulnerability
Data source: MITRE ATT&CK® Framework —attack.mitre.org